Technical information
We are offering modern and innovative facade system. This system of ventilated facades has long duration, is easy to install and improves aesthetic appearance of the facade. Natural stone, stone tiles and other desired materials can be used for the finish. Finishing materials are being fastened using fasteners in our facade system and those fasteners are being painted the same color as the finishing materials or alternatively the glue system is being used which covers fasteners totally.
Fastening of finishing materials using fasteners
This way of fastening is one of the easiest and most reliable. Aluminium consoles are being fastened to the masonry wall using masonry stud and they hold the aluminium profile. Aluminium profiles Land T are being laid on the installed consoles and screwed up. Fasteners are being fastened to the holding profile using rivets (rivets must be produced from the stainless steel). A plate is being mounted on the fasteners and it should be hold tight. Stainless steel fasteners are being painted into the colour chosen according to the finishing materials.
When finishing materials are being glued
This system is one of the most cost effective ways of fastening finishing materials to the hidden facade. The finishing materials are being glued to the aluminium profiles using the glue. The surfaces of the profiles and finishing materials should be cleaned using cleaner first of all. After the surfaces are cleaned the sticky installation tape is being glued to the profile and this tape holds the finishing materials until the hardening of the glue. The glue is being applied from the top downwards.
Aliuminum profiles
Aluminum consoles are being fastened to the masonry wall using masonry stud and they hold the aluminum profile. Aluminum profiles Land T are being laid on the installed consoles and screwed up. Ends of the profiles should be in the same level. There should be 15 mm gap left between the ends of the profiles. Two types of consoles are being used: steady type that are holding the weigh and wind load; and flexible type which allows longitudinal increase or decrease of the aluminum profile as the air temperature changes. As the aluminum profiles are being screwed up to the consoles, the insulation material (mineral wool) is being laid. The gap between finishing material and insulation must be at least 20 mm. Finishing materials (stone tiles) are fastened using stainless steel fasteners to the aluminum profile by the means of the rivets or by gluing.
Aluminium profiles are being fastened to the wall the same way as they are in system with fasteners.
![]() | A - Finish B - Holding Profiles C – Insulation (Mineral wool) D - VST flexible console E - FPL steady console F - Hole for the masonry stud
|
|
Profiles for System of Ventilated Facades
![]() | ![]() | ![]() |
| Profile L20x20x2 Profile L30x30x2 Profile L40x40x2 Profile L50x50x2 Profile L45x45x2 | Profile L60x40x2 | Profile FU462-43 |
![]() | ![]() | ![]() |
| Profile FU461-43 | Rustless steel | Rustless steel |
![]() | ![]() | |
| Console VST 160/70/3 Console VST 120/70/3 Console VST 60/70/3 | Console FPL 160/70/3 | Profile T60x80x3 |
Aluminium fin

Aluminium fin, EN AW-505 A, H14 (Al Mg 1 F15), surface decoration – anode polish, EN 573-3, 485-1/-2/-4.
Storage

Tvirtinimo profiliai
| Montažinis kampas 2- 3 mm storio cinkuota skarda. Tvirtinamas prie sienos 3 varžtais | ![]() | 1. min 80 mm 2. pagal apšiltinimo medžiagos storį 3. min 100 mm |
Horizontalus profilis "L"
| 1- 1,2 mm storio cinkuota skarda. Tvirtinamas prie montažinio kampo 3 varžtais: 1. 50 mm | ![]() |
Vertikalus profilis "Ω"(omega
1 mm storio cinkuota skarda. 1. min 70 mm | ![]() |
Vėdinimas
Vėdinimo tarpas, tarp apšiltinimo medžiagos (arba sienos) ir plokštės turi būti ne mažesnis kaip 20 mm;
Oro cirkuliacija yra privaloma, paliekant oro patekimo angą pastato apačioje ir viršuje:
iki 5 m aukščio pastate 25 cm²/m';
virš 5 m aukščio pastate 50 cm²/m'.
Tvirtinimas
Extoriet plokštės matmenys 3050 x 1300 x 6 mm. Prieš pradedant tvirtinimą, svarbu Extoriet plokštes kalibruoti: nuo kiekvienos kraštinės apie 1,5 cm.
EXTORIET fasado danga tvirtinama pasirinkus vieną iš būdų: prisukimo arba kniedijimo. Technologiškai šie būdai yra identiški, tik vienu atveju EXTORIET plokštė prisukama varžtais, kitu atveju – prikniedijama kniedėmis.
– Atstumas tarp tvirtinimo taškų priklauso nuo pokštės storio, pastato aukščio ir montavimo tipo.
– Paprastai pastato kampai kenčia nuo vėjo apkrovų, dėl to reikalinga daugiau tvirtinimo taškų. Rekomenduojama atstumą tarp tvirtinimo taškų sumažinti 10%.
Karkasas
1. Fasado danga Extoriet; | ![]() |
Plokštės tvirtinimo taškų atstumai
Storis – 6 mm | ![]() |
Tvirtinant dangą, plokštėje gręžiama 1,7 karto didesnė kiaurymė negu tvirtinimo elemento diametras.
(Pvz.: naudojant 4,8 mm diametro varžtą ar kniedę, plokštėje gręžiama 8 mm kiaurymė).
Tvirtinant dangą kniedėmis, kniedikliai turi būti su specialia galvute, kad per daug neužspaustų plokštės.
Tvirtinant dangą varžtais, pilnai prisukus būtina juos atsukti atgal 180° laipsnių
(pusė apsisukimo).
Plokštės tvirtinamos paliekant tarp jų mažiausiai 6 mm tarpą.
Tvirtinant dangą ant pastatų, aukštesnių nei 8 metrai, atstumas tarp tvirtinimo taškų sumažėja 20 %. (Pvz.: 6 mm storio: A=440, B=320 ir t.t.);
Tvirtinant dangą ant pastatų aukštesnių nei 20 metrų, atstumas tarp tvirtinimo taškų sumažėja 50 %. (Pvz.: 6 mm storio: A=275, B=200 ir t.t.).
Tvirtinimas prie karkaso
1. Išorės siena | ![]() |
Angokraščiai 1. Išorės siena | Horizontalus pjūvis 1. Išorės siena2. Apšiltinimo medžiaga PAROC IL 3. Vėjo izoliacija PAROC WAS 35 4. Apšiltinimo medžiagos ir vėjo izoliacijos tvirtinimo detalė 5. “Omega” tipo vertikalus profilis 6. EXTORIET plokštė 7. Kniedė arba varžtas |
DĖMESIO ! Tvirtinant fasado apdailos plokštę po ja negali būti vertikalių "omega" profilių jungties: |
Neteisingas tvirtinimas | Teisingas tvirtinimas |
![]() | ![]() |